12V 460Ah V2 Elite Series LiFePO4 Battery (5.89kWh): 12.8V nominal, 460Ah and 5,888Wh (5.89kWh) of nominal stored energy in one managed case with one BMS, so a large house bank needs fewer interconnects and cleaner routing than a bank of smaller batteries. A deep-cycle battery for house power and energy storage, not engine starting.

  • price-tag logoNew Launch
Regular price $2,399.00
Regular price $2,399.00 Sale price $2,399.00
Save: $0.00 (0% Off)*
Sale Sold out
Shipping calculated at checkout (Free shipping above $100)
  • cargo-truck logoFree shipping Over $99
Sold in last hours
  • free logo
    Fast, FREE Delivery

    Free, Fast, Doorstep Delight!

  • return logo
    Delivery & Returns

    Effortless Delivery, Easy Returns

View full details
  • Overview
  • Details
  • Accessories
  • 5.89kWh Stored Energy
  • 230A Continuous Output
  • 3,500+ Cycles Lifespan
  • IP67 Immersion-Rated
  • Heated Cold Weather Ready
  • 11 Year Limited Warranty

  • 12V 460Ah V2 Elite Series LiFePO4 Battery (5.89kWh): 12.8V nominal, 460Ah and 5,888Wh (5.89kWh) of nominal stored energy in one managed case with one BMS, so a large house bank needs fewer interconnects and cleaner routing than a bank of smaller batteries. A deep-cycle battery for house power and energy storage, not engine starting.
  • Dimensions & Fit: 20.86" L x 8.65" W x 12.06" H (529.8 x 219.8 x 306.3 mm; the height includes the terminal posts), 97 lb (approx. 44 kg). Install it upright. Replacing a Group 8D lead-acid battery? Confirm tray fit, hold-down and lid clearance against these dimensions first; the optional Epoch V2 & V2-T Mounting Hardware (8D battery bracket, sold separately) fastens to the six M8 nuts on the case.
  • Native VICTRON Communications: CAN bus at 500 kbit/s to a compatible Victron GX device (Cerbo GX, Ekrano GX or Cerbo GX Mk2). The battery reports its status and charge limits, and with DVCC on it sets the charge voltage and current limits of Victron chargers. The communication harness is included; set the DIP switches and GX settings per the manual.
  • Elite Performance Specifications: 230A continuous discharge and 230A continuous charge (0.5C, also the recommended rate), about 2,944W DC at 12.8V before inverter losses. Peak discharge of 500A for 30 seconds and 1,300A for 1 second for inverter surge; up to 400A charge for 5 seconds.
  • BLUETOOTH Battery Intelligence: Bluetooth 4.0 through the included battery gauge. The Epoch Li-Ion app (iOS and Android) shows state of charge, voltage, current, cell voltages, temperatures, history and warnings, and installs firmware updates over the air. External power button and battery gauge included.
  • HEATED For Extreme Climates: LiFePO4 cells must not be charged below 0°C (32°F). When a charger is connected and the cells are too cold, the BMS holds off charging while the internal heater, powered by the charge source, warms them; charging resumes at 5°C (41°F). With self-heating, charging is supported from -30°C (-22°F) ambient. Discharge works down to -20°C (-4°F).
  • IP67 Rated Enclosure: Dust-tight and protected against temporary immersion in up to 1m of water for 30 minutes. It is not rated for water jets, pressure washing or continuous submersion: install it where it stays dry in normal use, with all harness connectors fully seated.
  • Scalable Banks: Up to 16 batteries in parallel (7,360Ah, 94.21kWh) or up to 4 in series (51.2V nominal), using matched C12460A batteries of the same age, capacity and state of charge. Series-parallel arrays are not covered by the published DIP switch settings; contact Epoch before designing one.
  • Advanced Smart BMS & Certifications: Over/under-voltage, overcurrent, short-circuit and high/low temperature protection, and a 400A internal fuse (UL 60691). UL 1642, UL 9540A and IEC 62619:2022 cells; CE and RoHS. The internal fuse does not replace system protection: install a DC-rated fuse or breaker close to the battery positive.
  • 3,500+ Cycle Life & 11-Year Limited Warranty: 3,500+ cycles to 70% remaining capacity at 25°C. Maintenance-free: no watering or equalizing, though regular inspection and 8–12 N·m terminal torque checks keep the system safe. Backed by an 11-year limited warranty (5 years of free repair or replacement, then 40% off MSRP on a replacement battery through Year 11); register within 90 days or keep your proof of purchase.

Recommended Charging Settings:

Program every charge source to these settings, including Victron equipment, so charging stays correct if CAN communication is lost:
- Charger type: Lithium (LiFePO4) compatible, CC/CV
- Bulk / absorption voltage: 14.2V
- Absorption time: 15 minutes per battery in the bank (for example, 60 minutes for four batteries)
- Float voltage: 13.5V
- Re-bulk voltage: 13.3V
- Equalization: Disabled
- Temperature compensation: Disabled (0 mV/°C)
- Charge current: 230A (0.5C) per battery, recommended and maximum continuous; up to 400A for 5 seconds
- BMS high-voltage cutoff: 14.6V. Never charge above 14.6V, and do not use lead-acid equalization, desulfation or repair modes.
- SOC recalibration: 14.6V (manual); a custom algorithm under Victron communication
- Charging temperature: 0°C to 55°C (32°F to 131°F) cell temperature; with self-heating, charging is supported from -30°C (-22°F) ambient. Below freezing the heater warms the cells first, so expect a delay before charge current flows.
- Alternators: use a DC-DC charger, or an alternator regulator set up for lithium, and follow the alternator manufacturer's guidance.

Victron GX setup:
- Set the DIP switches on every battery (see the user manual).
- Fit the harness plug with the waterproof bung into the Master battery's blue port.
- For a bank, run an RJ45 cable from the Master's black port to Slave 1's blue port, then from Slave 1's black port to Slave 2's blue port, and so on, up to 16 batteries in parallel.
- Plug the harness's grey RJ45 plug into the GX device's BMS-CAN port (Cerbo GX or Ekrano GX). On a Cerbo GX Mk2, use VE.Can 1 or VE.Can 2.
- If you use a VE.Can port, open Settings > Services > VE.Can on the GX device and set the port speed to 500 kbit/s.
- Switch on the batteries.
- On the GX device, turn on DVCC, set the controlling BMS to Epoch and set the battery monitor to Epoch.
- Check that the Epoch battery appears in the device list, that the number of modules online equals the number of batteries installed, and that the installed capacity (Ah) equals the bank capacity, for example 1,840Ah for four batteries.
- While charging (not while inverting), the inverter tile shows External control. Under DVCC the system charges to 14.2V, holds absorption for at least about 15 minutes per battery, then floats at 13.5V.
- Manually program the MultiPlus, Quattro and every other charge source to the settings above as a fallback.

Compatibility: 

The Epoch Batteries C12460A (12.8V 460Ah V2 Elite Series LiFePO4) compatibility and incompatibility breakdown is listed below:
Compatible With
  • 12V, 24V, 36V & 48V House & Off-Grid Systems. Marine house banks, RVs, camper vans, skoolies, solar storage, and backup power setups (5.89kWh per battery).
  • Series & Parallel Expansion. Up to 4 batteries in series (for 24V, 36V, or 48V banks) or up to 16 batteries in parallel at 12V (7,360Ah / 94.2kWh) using matched C12460A batteries.
  • 2,500W–3,000W Class 12V Inverters. Rated for 230A continuous discharge (~2,944W DC) with high surge capacity (500A for 30 seconds; 1,300A for 1 second) for rooftop A/C units, microwaves, and induction cooktops.
  • Victron GX Ecosystems. Features native Victron CAN-bus communication (500 kbit/s) for plug-and-play closed-loop DVCC control with Cerbo GX and Ekrano GX (connects to BMS-CAN or VE.Can ports).
  • Wet & Harsh Marine Environments. IP67 dust-tight and immersion-rated enclosure (waterproof up to 1 meter for 30 minutes).
  • LiFePO4 Chargers & Cold Weather. Compatible with LiFePO4 AC converters, MPPT solar controllers, and DC-to-DC alternator chargers up to 14.6V (230A max charge). Internal self-heating enables safe charging down to -30°C (-22°F).
  • BCI Group 8D Bays. Fits standard Group 8D compartments (20.86" L × 8.65" W × 12.06" H, 97 lbs) and pairs with the Epoch V2 & V2-T 8D Battery Bracket.
  • Included Gauge & Mobile App. Includes an external power button and Bluetooth-enabled State of Charge gauge that pairs with the Epoch Li-Ion app (iOS and Android).
Not Compatible With
  • Engine Cranking / Starting. Deep-cycle house battery only; not rated or intended for vehicle, boat outboard, or generator starter motors.
  • Direct Alternator Wiring. Cannot be connected directly to an unregulated vehicle/marine alternator without a LiFePO4-programmed DC-to-DC charger or external alternator regulator.
  • Mixed-Model Battery Banks. Cannot be wired in series or parallel with lead-acid batteries or different Epoch models/capacities (such as the Essential Series 12460A-H).
  • Low-Clearance 8D Boxes. At 12.06" tall, it is ~3.5 inches taller than the Essential Series 12460A-H (8.60" H) and will not fit shallow under-seat or low-height 8D trays.