12V 460Ah V2-T Elite Series LiFePO4 (5.89kWh): Massive 5.89kWh of nominal stored energy engineered to replace multiple smaller batteries in premium marine house banks, luxury RVs, and off-grid solar systems.

  • price-tag logoNew Launch
Regular price $2,599.00
Regular price $2,599.00 Sale price $2,599.00
Save: $0.00 (0% Off)*
Sale Sold out
Shipping calculated at checkout (Free shipping above $100)
  • cargo-truck logoFree shipping Over $99
Sold in last hours
  • free logo
    Fast, FREE Delivery

    Free, Fast, Doorstep Delight!

  • return logo
    Delivery & Returns

    Effortless Delivery, Easy Returns

View full details
  • Overview
  • Details
  • Accessories
  • 5.89kWhStored Energy
  • 230A Continuous Output
  • 3,500+ Cycles Lifespan
  • IP67 Immersion-Rated
  • Heated Cold Weather Ready
  • 11 Year Limited Warranty


  • 12V 460Ah V2-T Elite Series LiFePO4 (5.89kWh): Massive 5.89kWh of nominal stored energy engineered to replace multiple smaller batteries in premium marine house banks, luxury RVs, and off-grid solar systems.
  • User-Serviceable 400A Class-T Fuse: The "V2-T" design integrates a user-serviceable 400A Eaton Bussmann JJN-400 Class-T fuse that reduces fault energy at the battery outlet in high-draw inverter setups. A main fuse or DC-rated breaker close to the battery positive terminal is still required for the downstream wiring.
  • Seamless Victron Integration: Native CAN communication (500 kbit/s) with Victron GX devices; with DVCC enabled, the BMS publishes its charge limits and state of charge for closed-loop charge management.
  • High-Output Discharge & Fast Charging: Delivers a heavy-duty 230A continuous discharge (500A peak for up to 10s) for 12V inverter systems in the 2,500W–3,000W class, while supporting a rapid 210A continuous charge rate.
  • IP67 Immersion-Rated & Internally Heated: Dust-tight IP67 enclosure rated for temporary immersion to 1 meter for 30 minutes with all seals, glands and port plugs installed, plus a 180.67W internal heater that uses incoming charger power to warm the cells for cold-weather charging (charging pauses at 0°C and resumes once the battery reaches 5°C).
  • Smart Bluetooth & State of Charge Meter Included: The included State of Charge meter shows state of charge, voltage and current, and houses the Bluetooth module for the free Epoch Cloud app (iOS and Android), which shows state of charge, cell voltage, temperature, cycles and system health alerts. An external power switch is also included.
  • Massive Bank Expansion: Wire up to 16 matched C12460A-A batteries in parallel for an ultra-high-capacity 12V bank (up to 7,360Ah / 94.2kWh), or up to 4 in series for a 48V-class string; series-parallel banks are not supported.
  • Advanced Smart BMS & UL-Certified Safety: Comprehensive internal protection against over-charge, over-discharge, over-current, short circuits, and temperature extremes, with certified components (UL 1642 and IEC 62619:2022 cells; UL 60691 internal fuse).
  • 3,500+ Cycle Life & 11-Year Limited Warranty: Rated for more than 3,500 cycles to 70% capacity (25°C, 0.5C charge, 1C discharge, 70% DoD) with no watering or acid service, backed by an 11-year limited warranty: free repair or replacement in Years 1–5, then 40% off MSRP on a replacement battery in Years 6–11. Register within 90 days or keep your proof of purchase.

Recommended Charging Settings: 

Batteries employed in non-Victron systems should utilize the following settings:
- Absorption voltage: 14.2V
- Absorption time of 15 minutes per battery
- Float voltage: 13.5V
- Equalization: Off
- No temperature compensation (Disabled)
- Max continuous charge current: 210A (0.45C), including all charge sources combined
- Charge termination (CC/CV): current ≤ 0.02C (9.2A)
- Alternators: a DC-to-DC charger programmed for LiFePO4 is highly recommended

To use the V2-T Elite with Victron systems.
Set up the battery comm harness and gauge as follows:
- Plug with waterproof bung plugged into master blue port.
- RJ45 cable out of master black port and into slave1 blue port.
- RJ45 cable out of slave1 black port and into slave blue port and so on to daisy chain up to 16 batteries in parallel.
- Set dip switches as per manual.

- Plug in grey RJ45 plug into the Cerbo or Ekrano GX BMS CAN port or if you have the new Cerbo Mk2 plug grey plug into VE-CAN1 or VE-CAN 2 and change the VE can port speed to 500 KBPS LV.

- To confirm proper reporting, go to the GX/touch screen and confirm the Epoch battery shows up on the device list. Click on the battery line, go to Details. Check to see the number of modules online is equal to the number of batteries installed. Check that the number of AH is equal to the number of AH installed.

- In the GX device/touch screen turn on DVCC, set controlling BMS to Epoch, set battery monitor to Epoch.

- The system should say External Control on the GX touch screen Inverter tile when charging (but not while inverting). The system will automatically cycle to 14.2V with an absorption time of a minimum of roughly 15 minutes per battery followed by 13.5V float voltage.

- It is recommended to manually program the Multiplus, Quattro and all other charge source to these same parameters in case of CAN communication loss.

Compatible Devices & Systems:
  • System Configurations: 12V parallel banks (up to 16 units) or 24V, 36V, and 48V series banks (up to 4 units).
  • Inverters: Pure sine wave inverters up to 2,500W–3,000W per battery (230A continuous discharge / 500A 30-second surge).
  • High-Draw Appliances: RV air conditioners, microwaves, induction cooktops, water heaters, and marine bow thrusters or windlasses (when powered via an appropriately sized inverter or DC circuit).
  • Chargers: LiFePO4-profile AC-DC converters, solar MPPT charge controllers, and inverter-chargers set to 14.2V absorption and 13.5V float.
  • Vehicle/Marine Alternators: Alternators paired with a DC-DC battery charger or an external lithium voltage regulator (such as Balmar or Wakespeed).
  • Monitoring & Comms: Victron GX devices (Cerbo GX, Ekrano GX) via 500 kbit/s CAN-bus (RJ45) and iOS/Android devices running the Epoch Li-Ion / Epoch Cloud app via Bluetooth.
  • Environments & Enclosures: Group 8D battery trays and wet or exterior compartments (IP67 waterproof/dust-tight; internal heater supports charging down to -22°F).
Incompatible Devices & Setups
  • Engine Starting: Marine inboard/outboard starters, RV chassis starters, or automotive cranking circuits (not a starting/CCA-rated battery).
  • Series-Parallel Wiring: Mixed series-parallel battery banks (must be wired strictly in series or strictly in parallel).
  • Lead-Acid / AGM Chargers: Chargers with automatic desulfation, equalization modes, or active temperature compensation enabled.
  • Direct Alternator Connections: Unregulated stock automotive or marine alternators wired directly to the battery without a DC-DC charger or external regulator.
  • Oversized Single-Battery Inverters: Inverters exceeding 3,000W continuous draw on a single battery (triggers the 230A BMS over-current protection).
  • Non-Victron Closed-Loop Comms: Non-Victron inverters or controllers expecting proprietary CAN protocols not mapped to the 500 kbit/s Victron standard.

Add your content here for Tab 1.22

Add your content here for Tab 1.

FEEDBACK

TESTIMONIALS